- All Products
- All Products
- Comfort 3 in 1 (Ceiling Integrated Fan)
Comfort 3 in 1 (Ceiling Integrated Fan)
http://www.dwellventilation.com/shop/comfort-3-in-1-comfort-3-in-1-ceiling-integrated-fan-2694 http://www.dwellventilation.com/web/image/product.template/2694/image_1920?unique=5c3b9d9Comfort 3-in-1 Ceiling Fan – Heat, Ventilate & Light with One Sleek Unit
- 3-in-one solution: heating, ventilation, and fresh air supply
- Powerful fast-heating function with adjustable temperature via RF remote
- Swinging air outlet for wider, 3D airflow (up to 168 m³/h) coverage
- Built-in dust filter and soft night light for added comfort
- Compact design fits integrated and regular ceilings – saves space, adds style
Ideal for modern bathrooms where comfort meets convenience.
Size: 4 Inch (100 mm) |
Application:
Comfort 3-in-1 Ceiling Fan – Heat, Ventilate & Light with One Sleek Unit
- All-in-one solution: heating, ventilation, and fresh air supply
- Powerful fast-heating function with adjustable temperature via RF remote
- Swinging air outlet for wider, 3D airflow coverage
- Built-in dust filter and soft night light for added comfort
- Compact design fits integrated and regular ceilings – saves space, adds style
Ideal for modern bathrooms where comfort meets convenience.
Product Specification:
Specification | Value |
---|---|
Voltage | 220V~50Hz |
Power (Heating) | 2100 W |
Power (Ventilating) | 30 W |
Power (Cooling) | 30 W |
Air Volume | 168 m³/h |
RPM | 1250 r/min |
Pressure | 100 Pa |
Noise | 45 dB(A) |
Duct Size | 100 mm |
Panel Size | 300×300 mm |
Design & Build
- Modern, compact design suitable for all bathroom aesthetics
- Durable ABS plastic housing, UV-resistant for long-lasting color and finish
- Smooth aluminum-finish panel blends with integrated ceilings
- Integrated swing outlet for wide-angle airflow distribution
- Night light function adds soft illumination in low-light bathrooms
- Built-in dust filter keeps internal components clean and ensures cleaner air circulation
- Panel Size: 300 × 300 mm — fits standard false ceilings
- Protection Rating: IPX2 – suitable for bathroom environments
Mounting & Compatibility
- Designed for integrated suspended ceilings and standard ceiling grids
- Duct outlet (Ø100 mm) connects to standard flexible ducting for fresh air supply
- Slim body profile allows easy mounting without reducing ceiling space
- Ideal for residential bathrooms, powder rooms, compact utility spaces.
Motor & Safety
- Reliable internal motor designed for continuous operation
- Constructed with silicon steel sheet and copper winding for durability
- Built-in overheat protection for safety during prolonged use
- Low power usage for ventilation and cooling, high efficiency for heating
- Designed for long maintenance-free operation
Control & Operation
- RF Remote Control for wireless adjustment of fan modes and temperature
- Independent control of heater, fan, and lighting functions
- Swinging air guide plate ensures 3D surround airflow
- One-touch night light can be activated as needed
- Smart temperature management makes it energy-efficient year-round
Ideal Applications
- Bathrooms, attached toilets, powder rooms, vanity zones
- Compact areas requiring combined heating + fresh air
- Homes, apartments, hotel washrooms, wellness centers
Parameter | Value (mm) |
A | 283.5 |
B | 127 |
C | 271 |
Hole Size | Dia 272~275 |
File | Download/ |
Product Catalog Dwell Comfort 3 in 1 | |
Installation Manual Comfort 3 in 1 | |
CAD file for product | |
Product Images |
We’re here to help.
Contact our expert design team.
Contact Us
Start with the customer – find out what they want and give it to them.
Application
1. Continuous or periodic exhaust ventilation of bathroom, showers, kitchens and other utility spaces.
2. Ventilation shaft mounting or duct connection.
3. Low to medium air flow motion for short distances at low air resistance.
4. Compatible with Ø 100-, 120-, 125- and 150-mm air ducts

Design
1. Modern design and aesthetic look.
2. The casing and the impeller are made of high-quality durable ABS plastic, UV resistant.
3. Various decorative plates for the front panel of the natural aluminum.
4. The intellectual impeller design makes the fan efficiency high and the service lifelong.
5. Protection rating IP34.
Mounting
1. The fan is mounted directly into the ventilation shaft.
2. In case of remote location of the ventilation shaft flexible air ducts may be used. The air duct is connected to the fan exhaust flange through a clamp.
3. Fixed to the wall by means of screws.
4. Suitable for ceiling mounting.
5. To connect a fan with a 12 V low voltage motor to 220 V/50 Hz power mains, it is necessary to purchase a step-down transformer (e.g. the TRF 220/12-25 transformer)
Motor
1. Reliable and low-watt electric motor.
2. Designed for continuous operation and requires no maintenance.
3. Equipped with overheating protection.
Speed Control
Manual:
1. The fan is controlled by a room light switch. It is not included in the delivery set.
2. The fan is controlled by the built-in pull cord switch V. Not applied in case of ceiling mounting.
3. Speed control is possible through a thyristor speed controller (see Electrical Accessories). Several fans may be connected to the same controller. Speed controllers can not be connected to the fans with Т, ТН, ТР, VТ, VТН modifications.
Automatic:
1. By the BU-1-60 electronic control unit. The control unit is supplied separately.
2. By the T timer (the built-in turn-off delay timer enables the fan operation within 2 to 30 minutes after the fan switching off).
3. By the humidity sensor and the TH timer (if the humidity level in the room exceeds the sensor threshold adjustable value within 60-90 % the fan switches automatically on and operates until the humidity level drops to the standard level, after that the fan continues operating within the time period according to the timer setting, then shuts down).
Start with the customer – find out what they want and give it to them.
Start with the customer – find out what they want and give it to them.
Parameter | Value |
Ø D | 100mm |
B | 152mm |
H | 120mm |
L | 126mm |
L1 | 130mm |

Application
1. Continuous or periodic exhaust ventilation of bathroom, showers, kitchens and other utility spaces.
2. Ventilation shaft mounting or duct connection.
3. Low to medium air flow motion for short distances at low air resistance.
4. Compatible with Ø 100-, 120-, 125- and 150-mm air ducts

Design
1. Modern design and aesthetic look.
2. The casing and the impeller are made of high-quality durable ABS plastic, UV resistant.
3. Various decorative plates for the front panel of the natural aluminum.
4. The intellectual impeller design makes the fan efficiency high and the service lifelong.
5. Protection rating IP34.
Mounting
1. The fan is mounted directly into the ventilation shaft.
2. In case of remote location of the ventilation shaft flexible air ducts may be used. The air duct is connected to the fan exhaust flange through a clamp.
3. Fixed to the wall by means of screws.
4. Suitable for ceiling mounting.
5. To connect a fan with a 12 V low voltage motor to 220 V/50 Hz power mains, it is necessary to purchase a step-down transformer (e.g. the TRF 220/12-25 transformer)
Motor
1. Reliable and low-watt electric motor.
2. Designed for continuous operation and requires no maintenance.
3. Equipped with overheating protection.
Speed Control
Manual:
1. The fan is controlled by a room light switch. It is not included in the delivery set.
2. The fan is controlled by the built-in pull cord switch V. Not applied in case of ceiling mounting.
3. Speed control is possible through a thyristor speed controller (see Electrical Accessories). Several fans may be connected to the same controller. Speed controllers can not be connected to the fans with Т, ТН, ТР, VТ, VТН modifications.
Automatic:
1. By the BU-1-60 electronic control unit. The control unit is supplied separately.
2. By the T timer (the built-in turn-off delay timer enables the fan operation within 2 to 30 minutes after the fan switching off).
3. By the humidity sensor and the TH timer (if the humidity level in the room exceeds the sensor threshold adjustable value within 60-90 % the fan switches automatically on and operates until the humidity level drops to the standard level, after that the fan continues operating within the time period according to the timer setting, then shuts down).
Start with the customer – find out what they want and give it to them.
Application
1. Continuous or periodic exhaust ventilation of bathroom, showers, kitchens and other utility spaces.
2. Ventilation shaft mounting or duct connection.
3. Low to medium air flow motion for short distances at low air resistance.
4. Compatible with Ø 100-, 120-, 125- and 150-mm air ducts

Design
1. Modern design and aesthetic look.
2. The casing and the impeller are made of high-quality durable ABS plastic, UV resistant.
3. Various decorative plates for the front panel of the natural aluminum.
4. The intellectual impeller design makes the fan efficiency high and the service lifelong.
5. Protection rating IP34.
Mounting
1. The fan is mounted directly into the ventilation shaft.
2. In case of remote location of the ventilation shaft flexible air ducts may be used. The air duct is connected to the fan exhaust flange through a clamp.
3. Fixed to the wall by means of screws.
4. Suitable for ceiling mounting.
5. To connect a fan with a 12 V low voltage motor to 220 V/50 Hz power mains, it is necessary to purchase a step-down transformer (e.g. the TRF 220/12-25 transformer)
Motor
1. Reliable and low-watt electric motor.
2. Designed for continuous operation and requires no maintenance.
3. Equipped with overheating protection.
Speed Control
Manual:
1. The fan is controlled by a room light switch. It is not included in the delivery set.
2. The fan is controlled by the built-in pull cord switch V. Not applied in case of ceiling mounting.
3. Speed control is possible through a thyristor speed controller (see Electrical Accessories). Several fans may be connected to the same controller. Speed controllers can not be connected to the fans with Т, ТН, ТР, VТ, VТН modifications.
Automatic:
1. By the BU-1-60 electronic control unit. The control unit is supplied separately.
2. By the T timer (the built-in turn-off delay timer enables the fan operation within 2 to 30 minutes after the fan switching off).
3. By the humidity sensor and the TH timer (if the humidity level in the room exceeds the sensor threshold adjustable value within 60-90 % the fan switches automatically on and operates until the humidity level drops to the standard level, after that the fan continues operating within the time period according to the timer setting, then shuts down).
Start with the customer – find out what they want and give it to them.